TSI Q-TRAK 7575 Indoor Air Quality Monitor
TSI Instruments

TSI Q-TRAK 7575 Indoor Air Quality Monitor

Pine Item #51216

Providing a comfortable, safe and healthy indoor environment is an increasingly important concern. Good air quality increases concentration and productivity. It can also reduce lost days due to absence. TSI's Q-TRAK™ Indoor Air Quality Monitor 7575 provides quick, accurate information to assess key indoor air quality (IAQ) parameters.

Features:

Simultaneously displays CO2 CO temperature and humidity measurements

Calculates dew point wet bulb and percent outside air

Large graphic display

One instrument with multiple plug-in probe options including VOC’s and air velocity

Store up to 39 days of data collected at one-minute log intervals

TRAKPRO™ data analysis software provided for data logging analysis and documenting results

Bluetooth communications for transferring data or remote polling

Displays up to 5 measurements

On-screen messages and instructions

Supports 12 different languages

Applications:

Simultaneously displays CO2 CO temperature and humidity measurements

Calculates dew point wet bulb and percent outside air

Large graphic display

One instrument with multiple plug-in probe options including VOC’s and air velocity

Store up to 39 days of data collected at one-minute log intervals

TRAKPRO™ data analysis software provided for data logging analysis and documenting results

Bluetooth communications for transferring data or remote polling

Displays up to 5 measurements

On-screen messages and instructions

Supports 12 different languages

Quantity must be 1 or more
Equipment available for both rental and purchase
Request a Quote

Specifications

Technical Specifications

Log Intervals1 second up to 1 hour (user selectable)
Barometric Pressure - Accuracy±2% of reading
% Outside AirRange - 0 to 100%\nResolution - 0.1%
Relative Humidity (IAQ Probe Models 980 and 982)Sensor Type - Thin-film capacitive\nRange - 5 to 95% RH\nAccuracy4 - ±3% RH\nResolution - 0.1% RH\nResponse Time - 20 seconds (for 63% of final
Temperature (IAQ Probe Models 980 and 982)Sensor Type - Thermistor\nRange - 0 to 60°C (32 to 140°F)\nAccuracy - 3 0.5°C (±1.0°F)\nResolution - 0.1°C (0.1°F)\nResponse Time - 30 seconds (
Carbon Monoxide (IAQ Probe Model 982)Sensor Type - Electro-chemical\nRange - 0 to 500 ppm\nAccuracy - ±3% of reading or 3 ppm whichever is greater\nResolution - 0.1 ppm\nResponse T
Time Constants1 sec 5 sec 10 sec 20 sec 30 sec (user selectable)
Meter Dimensions9.7 cm × 21.1 cm × 5.3 cm (3.8 in. × 8.3 in. × 2.1 in.)
Logging Capability - RangeLogs up to 56035 data points with key (4) measured\nparameters enabled 39 days at 1-minute log intervals
Storage Temperature-20 to 60°C (-4 to 146°F)
Operating Temperature5 to 45°C (40 to 113°F)
Barometric Pressure - Range517.15 to 930.87 mm Hg (20.36 to 36.648 in. Hg)
Carbon Dioxide (IAQ Probe Models 980 and 982)Sensor Type - Dual-wavelength NDIR (non-dispersive infrared)\nRange - 0 to 5000 ppm\nAccuracy6 - ±3.0% of reading or ±50 ppm whichever is gr

Dimension

USMetric
Probe Dimensions - Length7.0178
Probe Dimensions - Diameter0.7519

Weight

USMetric
Weight - with Batteries0.80.36